Fire Safety for Pubs, Restaurants and Hotels: What to Check Before Your Busiest Season

fire safety hospitality essex

Hospitality venues carry a fire risk profile that very few other businesses do. You have naked flames and hot oil running for hours at a time, a public who do not know the layout of the building, alcohol in the mix, seasonal staff who started last week, and at the busiest moments of the year you are operating at full capacity with the furniture rearranged.

Then add the final quarter. Occupancy climbs, private functions fill rooms that normally sit empty, decorations go up, heaters come out, and kitchens run harder than at any other point in the calendar. Every one of those factors pushes risk upward at the same time.

The sensible time to deal with it is now, before trade peaks, while you still have the quiet hours to put things right. This guide covers what matters most for pubs, restaurants, hotels and guest accommodation, and where we most often find problems when we assess these premises.

Why hospitality is treated as higher risk

Under the Regulatory Reform (Fire Safety) Order 2005, the responsible person is whoever has control of the premises. For a hospitality business that is usually the operator, the licensee or the company, and in a leased site the duty may be shared with the landlord. Our guide to fire safety legal responsibilities explains how that works in practice.

What makes hospitality different is who is in the building. Your occupants are members of the public who have never seen your floor plan, may have been drinking, and will instinctively try to leave through the door they came in rather than the nearest fire exit. Where you also provide sleeping accommodation, the risk rises again, because people are far more vulnerable when asleep and considerably slower to respond.

That is why there is dedicated government guidance on fire risk assessment for sleeping accommodation, published under Article 50 of the Fire Safety Order. It covers guest houses, bed and breakfasts, holiday accommodation and workplace areas where staff sleeping in is a condition of employment, which includes licensed premises and hotels. If you have rooms above the pub, it applies to you. Larger or more complex hotels sit beyond what that guide is written for and need a more detailed assessment by someone competent.

The kitchen is your single biggest exposure

If you only fix one thing this autumn, make it the extraction system. Grease builds up continuously on the inside of canopies, filters, ductwork and fans, it is highly flammable, and a flare up on the cooking line can ignite it and carry fire through the duct into concealed parts of the building where nobody can see it and standard suppression cannot reach it.

The recognised standard is TR19 Grease, published by the Building Engineering Services Association. It sets out how grease accumulation should be controlled and how often systems should be cleaned based on how heavily the kitchen is used. Most commercial insurance policies for food businesses require compliance with it, and many leases now write it in as an explicit obligation.

Practical points that get missed:

  • Cleaning frequency follows usage, not habit. A kitchen running all day needs cleaning far more often than one serving a short lunch trade. An annual clean is the floor, not the norm.
  • The whole run has to be cleaned. Canopy, filters, ductwork along its full length including bends, and the extract fan. A canopy clean on its own is not TR19 compliance.
  • You need access panels. If the ductwork cannot be reached, it cannot be cleaned or verified, and that gap will sit in your records.
  • Keep the certificate. Insurers, environmental health and fire officers all ask for it, with grease measurements and before and after evidence.
  • Check the suppression system and interlocks. Where a wet chemical system is fitted over the cooking line, confirm it is in service date and that gas interlocks actually isolate the supply.

Front of house during peak trade

Most front of house failures are not equipment faults. They are the result of a busy venue making small, reasonable decisions that quietly undo the fire strategy.

  • Escape routes narrowed or blocked. Extra covers squeezed in, high chairs stacked by a fire exit, deliveries left in a corridor during service, coat rails across a route. Capacity is set by your means of escape, not by how many chairs will physically fit.
  • Fire exits locked or obstructed from outside. Bins, kegs, pallets and parked vehicles behind the building are a recurring one. The route has to work all the way to a place of safety.
  • Decorations and naked flames. Tea lights on tables, decorative greenery near heat sources, drapes and fabrics with no flame retardant treatment, and lighting runs on overloaded extension leads.
  • Patio heaters, marquees and outdoor areas. Gas cylinders stored badly, heaters too close to canopies or structures, and temporary structures that change how people get out.
  • Fire doors wedged open. Service pressure is the most common reason fire doors stop working. Our article on why fire door maintenance matters as much as installation covers what to look for, and fire door inspections and common issues found goes into the defects we see most.

If you run functions, remember that a room laid out for a seated dinner, a standing reception and a live act are three different evacuation problems. The layout you assessed in March may not be the layout you are running in December.

Hotels and guest accommodation

Sleeping risk changes the whole picture, because evacuation depends on detection waking people who are unfamiliar with the building, often at night, often with minimal staff on site.

  • Detection coverage. Automatic fire detection in bedrooms, corridors and escape routes, with a weekly alarm test from a different call point each time, routine servicing, and every test written up in the fire log book.
  • Bedroom doors. Guest room doors are fire doors. Self closing devices get disabled because guests find them heavy, which removes the protection the escape corridor depends on.
  • Protected corridors and compartmentation. Refurbishment work, cabling, new television points and pipework routinely breach compartment lines above ceilings. This is why compartmentation surveys matter in older and much altered buildings.
  • Night staffing. Your evacuation plan has to work with the number of people actually on shift at 3am, not with a full daytime team.
  • Guests who need assistance. You need a way to identify them at check in and a plan for assisting them, including any guest with reduced mobility placed on an upper floor.

Staff training is the weak point in a seasonal business

Hospitality runs on high staff turnover, and the final quarter brings in temporary and agency people exactly when the building is fullest. A member of staff who has had no fire induction is not going to direct sixty guests out of a secondary exit they have never used.

Everyone working the floor should know where every exit is, not just the main one, what the alarm sounds like, where the assembly point is, and who takes charge. Kitchen staff need to know how to isolate gas and what not to do with a fat fire. At least one rehearsed evacuation before peak season is worth more than any amount of paperwork.

Where we see hospitality venues fall short

The same findings come up repeatedly across the sector.

  • A fire risk assessment that predates a refurbishment, a change of layout or a new kitchen
  • Extraction cleaned to canopy level only, with no certificate covering the full duct run
  • Emergency lighting never tested, so escape routes go dark in a power failure
  • Cellars, storerooms and roof voids used as overflow storage with no fire separation
  • Alarm testing and training records that stop several months ago
  • Staff accommodation above the trading area treated as an afterthought

Several of these overlap with the issues in our article on the top fire safety mistakes businesses commonly make, which is worth a read alongside this one.

Your pre season checklist

  1. Confirm when your fire risk assessment was last reviewed and whether anything has changed since
  2. Get a dated TR19 certificate for the full extraction system and book the next clean
  3. Walk every escape route from the furthest point to the street, at night, as a guest would
  4. Check every fire door closes and latches, and remove every wedge
  5. Test emergency lighting and the alarm, and write it down
  6. Brief all seasonal staff before their first shift, not after
  7. Reassess any function layout that differs from your normal trading layout

If you would rather have someone competent look at it properly, our article on what to expect during a professional fire safety inspection sets out how the process runs.

Alden Fire Consultants provides fire risk assessments, fire door inspections, compartmentation surveys and fire safety training for hospitality businesses across Essex, London, Kent, Suffolk and Hertfordshire. Our consultants are IFE registered, report in plain language rather than jargon, and prioritise every finding so you know what has to be put right before trade peaks and what can safely wait.

To get your venue reviewed before your busiest weeks, get in touch with our team or call 020 3150 1193 for a free initial consultation.

Frequently asked questions

How often does a pub or restaurant need a fire risk assessment?

There is no fixed interval in law, but the assessment must be kept current. An annual review is the practical standard, with an immediate review after any refurbishment, change of layout, change of use or new kitchen equipment.

Is TR19 Grease a legal requirement?

TR19 Grease is an industry specification rather than legislation. However, the Fire Safety Order requires you to control fire risk, and TR19 is the accepted means of demonstrating you have controlled grease accumulation. Most insurers and many leases require compliance with it directly.

Do we need a separate assessment for rooms above the pub?

Not a separate assessment, but your existing one must properly cover the sleeping accommodation, because the risk profile and the escape arrangements are different from the trading areas below.

Can we use candles on tables?

There is no outright ban, but naked flames need controlling. That means stable enclosed holders, no contact with decorations or fabrics, a rule on who lights and extinguishes them, and the arrangement recorded in your fire risk assessment.