Residential buildings sit under the heaviest fire safety regulation of any property type in England, and the rules have moved again this year. If you own, manage or act as the responsible person for a block of flats, what was compliant in 2023 is not necessarily compliant now.
The changes are not minor housekeeping either. Since 6 April 2026, responsible persons for many residential blocks have had a legal duty to identify residents who cannot evacuate without help, offer them an individual assessment and agree a written plan for what they should do in a fire. That is a genuine shift in what fire safety management in a residential setting actually looks like day to day.
This guide sets out who carries the legal duty, what the law now requires at each building height, what changed in April, and where most blocks fall short in practice.
Who is the responsible person in a block of flats
Fire safety law in England and Wales does not reach inside individual flats. It applies to everything else: the communal stairwells, corridors, plant rooms, bin stores, roof spaces, the structure itself, the external walls and the flat entrance doors.
Whoever has control over those parts is the responsible person. In practice that is usually the freeholder, the management company, the managing agent, or a resident management company board. Where control is split between several parties, each one holds duties for the parts they control and they are required to co operate with each other.
The point that catches people out is that appointing a managing agent does not transfer the legal duty away from the freeholder. Responsibility can be shared, but it cannot simply be handed over and forgotten. We covered how this works across all premises types in our guide to fire safety legal responsibilities.
The four pieces of legislation that apply
Residential fire safety in England is governed by layers of law that have built up since 2005, and they all still apply at the same time.
- The Regulatory Reform (Fire Safety) Order 2005. The foundation. It requires a suitable and sufficient fire risk assessment of the common parts, and general fire precautions to be put in place and maintained.
- The Fire Safety Act 2021. Confirmed that the Order covers the building structure, the external walls including cladding and balconies, and flat entrance doors. This closed the argument some duty holders had been making that external walls sat outside their remit.
- The Fire Safety (England) Regulations 2022. Introduced specific, prescriptive duties that scale with building height. These are the checks and records enforcing authorities look for first. Note that while the 2005 Order applies across England and Wales, these additional duties apply in England only.
- The Building Safety Act 2022. Created the higher risk building regime for blocks at least 18 metres tall or with at least seven storeys and two or more residential units, including registration with the Building Safety Regulator and a safety case report.
What you must do, by building height
The 2022 Regulations are tiered. Working out which tier your building sits in is the first practical step, because the duties stack as the building gets taller.
All buildings with two or more flats
- Provide residents with fire safety instructions, including the evacuation strategy for the building and how to report a fire
- Give residents information on the importance of fire doors and their duty not to compromise them
- Repeat that information at least every twelve months and give it to every new resident when they move in
Buildings above 11 metres
- Quarterly checks of all fire doors in the common parts
- Annual checks of flat entrance doors, on a best endeavours basis where access is refused
Buildings at least 18 metres or seven storeys
- Monthly checks of lifts intended for firefighter use and other key firefighting equipment, with any fault lasting more than 24 hours reported to the fire and rescue service
- A secure information box on site containing the current building plans and responsible person contact details
- Floor plans and a building plan supplied to the local fire and rescue service
- Wayfinding signage visible in low light conditions on every storey
- Information provided on the design and materials of the external wall system
Records matter as much as the checks themselves. An enforcing authority cannot see a check that happened but was never written down. If you are unsure how thoroughly this gets examined, our article on what to expect during a professional fire safety inspection walks through the process.
What changed on 6 April 2026: Residential PEEPs
The most significant development this year is the arrival of Residential Personal Emergency Evacuation Plans, introduced by the Fire Safety (Residential Evacuation Plans) (England) Regulations 2025. They implement a recommendation made by the Grenfell Tower Inquiry in its Phase 1 report back in 2019.
Which buildings are in scope
The regulations apply to buildings containing two or more sets of domestic premises which are either:
- At least 18 metres above ground level, or with at least seven storeys, or
- More than 11 metres above ground level and operating a simultaneous evacuation strategy
That second category is the one people miss. A block that moved off stay put onto simultaneous evacuation because of a cladding or compartmentation issue is now in scope even though it is well under 18 metres.
What the responsible person has to do
- Identify relevant residents. Make reasonable efforts to find out who in the building may be unable to evacuate without assistance, whether because of reduced mobility, a sight or hearing impairment, a long term health condition or a cognitive condition.
- Offer a person centred fire risk assessment. Each relevant resident must be offered one, and it must be carried out where the offer is accepted.
- Put mitigation in place. Identify measures that can reasonably and proportionately reduce the risks the assessment finds.
- Agree an emergency evacuation statement. A written record, agreed with the resident, setting out exactly what they should do if there is a fire.
- Share information with the fire service. With the resident’s clear and informed consent, provide the local fire and rescue authority with basic details of who may need assistance.
- Produce a building emergency evacuation plan. A building wide plan that integrates individual arrangements, reviewed at least every twelve months and, where applicable, kept in the secure information box.
Person centred assessments must be reviewed every twelve months, or sooner if a resident’s circumstances change. Essex County Fire and Rescue Service has confirmed it will check for compliance during fire safety audits, and the same position is being taken by fire and rescue services nationally. Further background is available from the House of Commons Library briefing on the regulations.
Residents are allowed to decline. That is not a compliance failure, provided you can evidence that a genuine offer was made and the response recorded.
Stay put only works if the building supports it
Most purpose built blocks in England were designed around a stay put strategy, where residents not directly affected by a fire remain in their flats while the fire is contained in the flat of origin. It is a sound strategy, but it depends entirely on the compartmentation of the building being intact.
Once compartmentation is compromised, whether by unsealed service penetrations, damaged fire stopping, defective fire doors or external wall issues, stay put stops being safe and the building usually has to move to simultaneous evacuation with interim measures until the defects are put right.
This is why compartmentation surveys matter so much in residential settings. The failures are almost always hidden above ceilings, inside risers and behind service routes, and they are frequently created by routine maintenance work rather than original construction.
Where residential blocks most often fall short
Across the residential work we carry out, the same issues come up repeatedly.
- Fire doors that no longer close. Failed self closing devices, damaged intumescent strips and excessive gaps around the leaf. Our article on fire door inspections and common issues found covers what a proper check involves.
- Communal areas used for storage. Bikes, pushchairs, mobility scooters and furniture in protected escape routes, which adds fire load exactly where there should be none.
- Fire risk assessments left to age. A block with ongoing works or a changed evacuation strategy needs its assessment revisited far sooner than annually. See how often you should review your fire risk assessment.
- No evidence trail. Checks carried out by contractors but never collated, so the responsible person cannot demonstrate compliance when asked.
- Assuming the 2026 duties only affect tall towers. The 11 metre simultaneous evacuation category brings in a large number of mid sized blocks.
Where to start
If you are responsible for a residential building and you are not certain where you stand, work through it in this order.
- Confirm the height and storey count of every building in your portfolio and identify which tier each one falls into
- Confirm the evacuation strategy in place for each building, and whether any block above 11 metres has moved to simultaneous evacuation
- Check that your fire risk assessment reflects the current condition of the building, including external walls and flat entrance doors
- Review your fire door check records against the quarterly and annual requirements
- Begin resident engagement for Residential PEEPs, since identification and consent take time to do properly
Alden Fire Consultants carries out fire risk assessments, fire door surveys, compartmentation surveys and fire strategy work for residential clients across Essex, London, Kent, Suffolk and Hertfordshire, including complex high rise schemes. Our consultants work with managing agents, freeholders and resident management companies to produce findings that are clear, proportionate and practical to act on.
If you would like your residential portfolio reviewed against current requirements, get in touch with our team or call us on 020 3150 1193 for a free initial consultation.
Frequently asked questions
Does fire safety law apply inside individual flats?
No. The Fire Safety Order covers the common parts, the structure, the external walls and the flat entrance doors. What happens inside a private dwelling is outside its scope, although social landlords carry separate duties under housing legislation.
Do Residential PEEPs apply to buildings under 18 metres?
They can. Any building over 11 metres containing two or more flats and operating a simultaneous evacuation strategy is in scope, regardless of whether it reaches 18 metres.
What happens if a resident refuses to take part?
Participation is voluntary for residents. The duty on the responsible person is to make a genuine offer and to record the outcome, so keeping evidence of the approach made is what protects you.
How often should a residential fire risk assessment be reviewed?
Annually as a minimum for most blocks, and immediately after any significant change to the building, its occupancy or its evacuation strategy. Buildings undergoing remedial works usually need more frequent review.